Topic: Curb Appeal Changes |
|
| dbbarron Replies: 35 Views: 42544 |
|
| Thanks for the candid advice. If only it were that easy to (1) find another house that meets (or can be modified to meet) our needs; or (2) find an architect with appropriate ideas.
We are going t ... |
|
Topic: Curb Appeal Changes |
|
| dbbarron Replies: 35 Views: 42544 |
|
| See attached pic - alternate left side roofline - perhaps has greater unity with main structure. Perhaps even a faux, low/wide dormer (no window - just gable front) on right side addition to tie-in. ... | |
Topic: Curb Appeal Changes |
|
| dbbarron Replies: 35 Views: 42544 |
|
| SDR: how would you envision the addition of space to the front of the structure?
Note, this will be limited by setback issues; also, multiple rear additions already in place, no easy room for more. ... |
|
Topic: Curb Appeal Changes |
|
| dbbarron Replies: 35 Views: 42544 |
|
| After much consideration of comments in this thread/forum, I attach the near complete front design with new entry and addition (left side - not sure if we are doing this yet). As much as there was op ... | |
Topic: Floorplan changes - addition consideration |
|
| dbbarron Replies: 8 Views: 15424 |
|
| Let me try to clarify:
System already in house as follows (pre addition) System 1: 80kbtu heat, 1.5 Ton Air; 2 zones Sys1 Zone 1:MBR SYS 1 Zone 2:Family Room Return air entirely in MBR, near ... |
|
Topic: Floorplan changes - addition consideration |
|
| dbbarron Replies: 8 Views: 15424 |
|
| A bit more information:
Heating/cooling is forced air. Two systems; 1)1.5 Ton;80kbtu for family room/master bedroom with return air in MBR 2)3 Ton; 150kBtu for rest of hour (LR/DR/Kit/small ... |
|
Topic: Floorplan changes - addition consideration |
|
| dbbarron Replies: 8 Views: 15424 |
|
| Yes | |
Topic: Curb Appeal Changes |
|
| dbbarron Replies: 35 Views: 42544 |
|
| To be clear on dimensions:
Finished wall to wall of entry foyer is 74"; one or two inches of (maybe unavoidable) trim yields 72" although you could conceivably tuck the jack studs for a header flus ... |
|
Topic: Curb Appeal Changes |
|
| dbbarron Replies: 35 Views: 42544 |
|
| Here are the consolidated preferred considerations top to bottom:
1. Oak door (no lites); 18" grid pattern; issue: only 54" width - I have more width than this, even with existing rough opening, bu ... |
|
Topic: Floorplan changes - addition consideration |
|
| dbbarron Replies: 8 Views: 15424 |
|
| After much help with entryway/curb appeal on this forum, I though I'd ask for comments regarding a proposed floorplan change as well - see reference pics of house in thread "Curb Appeal Changes"
T ... |
|
Topic: Curb Appeal Changes |
|
| dbbarron Replies: 35 Views: 42544 |
|
| Thanks for continued advise - will render 5 piece design tonite (on aside, friend also suggested picture window with grids to match entry in office window (right of lr)). This would yield 1 foot sq. ... | |
Topic: Curb Appeal Changes |
|
| dbbarron Replies: 35 Views: 42544 |
|
| Floor to ceiling is 15' tall side, 14' short side.
Checking loading with pella for needed headers/bracing if any. Wife and I pondering ##3 and ##4; single door config definitely matches (origina ... |
|
Topic: Curb Appeal Changes |
|
| dbbarron Replies: 35 Views: 42544 |
|
| See various simulations consistent with the discussion.
Going left to right, top to bottom 1. oak door, lower glazing opaque, upper clear 2. full light door, lower glazing opaque, upper clear ... |
|
Topic: Curb Appeal Changes |
|
| dbbarron Replies: 35 Views: 42544 |
|
| A quick review of the pella arch. specifications suggests no problem stacking their systems directly on top of an entry door for the sizes at issue here; that plus custom grills, assuming they have ob ... | |
Topic: Curb Appeal Changes |
|
| dbbarron Replies: 35 Views: 42544 |
|
| Thanks-
1)Vinyl siding, roof line trip and beam ends are flashed in aluminum. Not painted. Perhaps some overlay trim pieces? 2)Wife and I were discussing lightly obscured glazing floor to ceili ... |
|