View previous topic :: View next topic
|
| Author |
Message |
lisa853
Joined: 04 Dec 2008 Posts: 2
|
Posted: Thu Mar 26, 2009 6:46 pm Post subject: Archi Student |
    |
|
Fellow Architects and Archi Students, I'm currently on a School Architectural Design project, it's A City Plaza.
Now the challenge, I'm concerned that any gush of wind will force its way through 1 or more of the spaces between these buildings at a time, and directed at the building at the centre. I believe these might become an architectural or environmental hazard if safety measures are not employed.
Pls I need suggestions on how to achieve a safe and practicable structure. _________________ Lost dvd set |
|
| Back to top |
|
 |
lekizz millennium club
Joined: 11 Jan 2006 Posts: 1212 Location: UK
|
|
| Back to top |
|
 |
nanrehvasconez
Joined: 25 Feb 2008 Posts: 329
|
Posted: Fri Mar 27, 2009 7:53 am Post subject: |
    |
|
When you design buildings or building complexes you have to follow the local and regional construction codes and ordenances, for example, in the USA Gulf Coat the predominant factor is the lateral wind loads velocity, (Design of Lateral Force Resisting Systems Using the 2006 International Building CodeWhether due to wind, low-seismic or high-seismic loading, the lateral force resisting system of a building is designed and constructed to resist racking, overturning, and sliding. It is this system that gives a building stability and defines its general behavior. Design begins with the International Building Code, which does not include all provisions but rather makes necessary reference to other technical and material standards to complete the picture.
In the Western states such as Alaska, California, Oregon and Washington the predominant factor for design are the SEISMIC loads (see UBC Earthquake Design) |
|
| Back to top |
|
 |
O-Archy
Joined: 18 Sep 2008 Posts: 48 Location: Victor, Idaho
|
Posted: Fri Mar 27, 2009 8:11 pm Post subject: |
    |
|
Ahem,
Not to digress...
But, LRFD (Load Resistance Factor Design and / or ASD (Allowable Stress Design) --edit-- Load Factor Resistant Design and Allowable Stress Design --edit-- I'm getting too old to remember the acronyms accurately...
are the code recognized methods for analysis of a structural ability...
Hire a licensed structural consultant in the specific jurisdiction.
Oh wait, this is the student fora...
Try a robust base of high mass material (stone), a mid body material with transparency windows in a spandrel wall, and a nice low profile "hat" for wind resistance. Perhaps no more than four stories tall, look into "A Pattern Language" for more specificity
OK Bye. _________________ "If the city is one of humankinds greatest achievements, it's uncontrolled evolution also can lead to desecration of both nature and the human spirit" -M.G. Marcus-1979 |
|
| Back to top |
|
 |
phalculus
Joined: 07 May 2009 Posts: 6
|
Posted: Thu May 07, 2009 3:00 pm Post subject: |
    |
|
| Don't you mean foru...? |
|
| Back to top |
|
 |
|